We work! Large selection of equipment for ventilation systems.
Catalog
Client
(044) 238-24-81
Our location:
6, Predprinimatelska str., Brovary, Kyiv region
Phones:
Working hours
  • shop
  • from 7:00 to 20:00 Mon - Fri
  • warehouse and accounting
  • Mon - Fri from 8:00 to 17:00
  • without a lunch break
E-mail
We are on social networks
Go to contacts
0 0
Catalog
Main page
Wishlist
0
Compare
0
Contacts

VCP 5-45 #4 w/motor AIR 112 M2 7.5 kW 3000 rpm, execution 1

The centrifugal fan of the dust

Brand: КВЗ
0
All about product
Description
Specification
Aerodynamic Characteristics
Reviews 0
Questions0
In Stock
Product Code: ID37526
22 968₴
Found cheaper?

Centrifugal dust fan series VCP 5-45 #4 with electric motor Electric motor AIR 112 M2 7.5 Power kW 3000 Vol./Min, adapted for execution scheme #1, impeller directly the motor shaft is made of carbon steel

Productivity, м³/h:3400
Pressure, Pa:2250
Delivery
Nova Poshta Nova Poshta
Delivery (saving 10% of the delivery cost) Delivery (saving 10% of the delivery cost)
Self-delivery Self-delivery
VCP 5-45 #4 w/motor AIR 112 M2 7.5 kW 3000 rpm, execution 1
22 968₴
Description

Centrifugal (radial) dust fan VCP 5-45 #4 (VCP 110-43) with electric motor Electric motor AIR 112 M2 7.5 Power kW 3000 Vol./Min, manufactured in configuration No. 1, with the impeller directly mounted on the motor shaft, made of carbon steel.

This fan is designed for transporting explosion-proof non-abrasive dust-air-gas mixtures with air temperatures not exceeding 80°C and aggressiveness towards carbon steel not greater than that of air; not containing sticky substances or fibrous materials. The maximum content of mechanical impurities in the transported medium is up to 300000 mg/m3 (1 kg/m3).

The dust fan VCP 5-45 #4 (VCP 110-43) is intended for removing wood dust and chips from woodworking machines, metal dust and chips from metalworking machines, as well as for sanitary and industrial applications in stationary conditions.

General information about dust fans VCP 5-45 #4 w/motor AIR 112 M2 7.5 kW 3000 rpm (VCP 110-43):

  • Single-sided suction
  • Rotatable spiral housing
  • Radial straight blades
  • Number of blades – 8 pcs
  • Rotation direction – right and left
  • Configuration: No. 1 – impeller mounted directly on motor shaft
  • Material: carbon steel

Application areas of dust fans VCP 5-45 #4 w/motor AIR 112 M2 7.5 kW 3000 rpm (VCP 110-43):

  • In dust collection systems
  • In pneumatic transport systems
  • For removing wood dust and chips from woodworking machines
  • For removing metal dust and chips from metalworking machines
  • For other sanitary and industrial purposes

Manufacturing options for centrifugal fans VCP 5-45 #4 (VCP 110-43):

  • Made of carbon steel
  • Made of stainless steel
  • Made of dissimilar metals

Design, main components and operating principle of dust fan VCP 5-45 #4 (VCP 110-43):

Housing (casing) VCP 5-45 #4

The spiral casing is a non-detachable construction.

A cylindrical inlet nozzle with a flange is attached to the front wall of the casing. The outlet nozzle is welded to the casing. The gap between the inlet nozzle and the impeller is adjustable.

Impeller of fan VCP 5-45 #4 (VCP 110-43)

The impeller is welded and consists of 8 radially arranged straight blades, a hub, and two side disks.

Asynchronous electric motor Electric motor AIR 112 M2 7.5 Power kW 3000 Vol./Min

The electric motor Electric motor AIR 112 M2 is a general-purpose three-phase asynchronous motor with a squirrel-cage rotor, designed for operation on an AC network with a frequency of 50 Hz and voltage of 220/380 V. The nominal rotation speed of the motor Electric motor AIR 112 M2 is 3000 rpm. Mounting dimensions (shaft height): 112 mm; shaft diameter: 32 mm; power in kW: 7.5; climate version: UZ; IP rating: 54. Housings of motors with power from 1.5 kW are cast from grey cast iron for reliability. Upon request, the motor Electric motor AIR 112 M2 can be made with a housing from silumin alloy.

Fans VCP 5-45 #4 (VCP 110-43) are available in right- and left-handed rotation. The rotation direction is defined from the inlet side: clockwise – right-hand rotation; counter-clockwise – left-hand rotation.

The operating principle of the fan is based on air movement due to the transfer of rotational energy from the impeller mounted on the shaft and driven by the motor.

When the impeller rotates, the air mixture entering the channels between the blades is pushed by centrifugal force to the periphery of the impeller and directed to the outlet part of the casing.

Housing orientation of radial fans with right (R) and left (L) rotation, view from the suction side:
Housing orientation for right and left rotation VCP 5-45 #4 w/motor AIR 112 M2 7.5 kW 3000 rpm

Specifications
Common
Model
VCP 5-45 #4
Productivity, м³/h
3400
Pressure, Pa
2250
Max. transported air temperature, °C
80
Pollution limits, mg/m3
300000
Weight, kg
105
Impeller revs, vol./Min
2870
The total sound power level, not more than, dB(A)
104
Electric motor AIR 112 M2
Common
Model
AIR 112 M2
Motor type
asynchronous
Kind
general purpose industrial motor
Motor series
AIR
Shaft diameter, mm
32
Voltage, V
220/380
Frequency of the current, Hz
50
Power kW
7.5
Vol./Min
3000
n, vol./Min
2880
Climatic performance
UZ
Class of protection, IP
54
Efficiency, %
85,4
Power factor, cosφ
0,88
Weight, kg
49
Consumed nominal current, In (A)
15,2
Dimension (height of rotation axis), mm
112
Phase
3-phase
The ratio of max. torque to rated power, Mmax/Mn
2,4
The ratio of starting current to the nominal, Istart/In
7,2
The ratio of starting torque to rated power, Mstart/Mn
2,2

Aerodynamic characteristics of VCP 5-45 #4 w/motor AIR 112 M2 7.5 kW 3000 rpm

Reviews

There are no reviews for this product.

There are no reviews for this product, be the first to leave your review.

Answers & questions
Add your question and we will answer as soon as possible.

No questions about this product, be the first and ask your question.