We work! Large selection of equipment for ventilation systems.
Catalog
Client
(044) 238-24-81
Our location:
6, Predprinimatelska str., Brovary, Kyiv region
Phones:
Working hours
  • shop
  • from 7:00 to 20:00 Mon - Fri
  • warehouse and accounting
  • Mon - Fri from 8:00 to 17:00
  • without a lunch break
E-mail
We are on social networks
Go to contacts
0 0
Catalog
Main page
Wishlist
0
Compare
0
Contacts

VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm, execution 1

Low pressure centrifugal fan

Brand: КВЗ
0
All about product
Description
Specification
Aerodynamic Characteristics
Dimensions
Reviews 0
Questions0
In Stock
Product Code: ID9026
86 338₴
Found cheaper?

Low-pressure centrifugal fan series VC 4-75 NZH #6,3 with electric motor Electric motor AIR 90 L6 1.5 Power kW 1000 Vol./Min. general industrial use, made according to the scheme of execution #1 of stainless steel AISI 403 for corrosive environments. Fan working point: 3190 m3/hour at a pressure of 465 Pa.

Productivity, м³/h:3190
Pressure, Pa:465
Delivery
Nova Poshta Nova Poshta
Delivery (saving 10% of the delivery cost) Delivery (saving 10% of the delivery cost)
Self-delivery Self-delivery
VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm, execution 1
86 338₴
Description

Series VC 4-75 NZH #6,3 low-pressure centrifugal fan (VR 88-72.1-5.5, VR 80-75-5) with corrosion-resistant electric motor Electric motor AIR 90 L6 1.5 Power kW 1000 Vol./Min, made of AISI 403 stainless steel for aggressive environments.

This fan is intended for ventilation or air-conditioning systems and other gas mixtures contaminated with aggressive gases and vapors—where the corrosion resistance of stainless steel exceeds that of standard carbon steel—and which contain no fibrous materials, sticky substances, dust, or other solid impurities in excess of 100 mg/m³ under moderate (U) climate (3rd placement category) and tropical (T) climate (2nd placement category) conditions in accordance with DSTU 15150.

The centrifugal fan VC 4-75 NZH #6,3 (VR 88-72.1-5.5, VR 80-75-5) consists of the following modules, which can be purchased separately:

  • Fan assembly VC 4-75 NZH #6,3 (VR 88-72.1-5.5, VR 80-75-5) without electric motor
  • Impeller wheel of fan VC 4-75 NZH #6,3 (VR 88-72.1-5.5)
  • Scroll casing of fan VC 4-75 NZH #6,3 (VR 80-75-5)
  • Electric motor Electric motor AIR 90 L6 1.5 Power kW 1000 Vol./Min for fan VC 4-75 NZH #6,3

General information about VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm centrifugal fans (VR 88-72.1-5.5, VR 80-75-5):

  • Low pressure
  • Single-suction
  • Backward-curved blades
  • Number of blades: 12
  • Direction of rotation – right and left
  • Fans are manufactured in accordance with TU U 28.2-24881057-003:2023
  • Construction material – stainless steel

Purpose of VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm centrifugal fans (VR 88-72.1-5.5, VR 80-75-5):

The VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm stainless-steel centrifugal fan is intended for moving air and other gas mixtures contaminated with aggressive gases and vapors—where the corrosion resistance of stainless steel exceeds that of ordinary steel—and which contain no sticky substances, fibrous materials, dust, or other solid impurities in excess of 100 mg/m³.

Applications of VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm (VR 88-72.1-5.5, VR 80-75-5) centrifugal fans:

  • Air-conditioning systems
  • Ventilation systems
  • Air-heating systems
  • Other sanitary and industrial uses

Operating conditions of VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm (VR 88-72.1-5.5, VR 80-75-5) centrifugal fan: Operates under moderate climate conditions at ambient temperatures from −40 °C to +40 °C. The temperature of the conveyed medium must not exceed 80 °C.

Principle of operation of VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm (VR 88-72.1-5.5, VR 80-75-5) centrifugal fan: Air, by energy imparted by the impeller blades, enters the fan under centrifugal force at a 90° angle and is directed radially into the spiral scroll casing; within the casing, the air under pressure follows a spiral path and is discharged through the fan outlet.

Delivery set of VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm (VR 88-72.1-5.5, VR 80-75-5) centrifugal fan:

  • Spiral casing
  • Impeller wheel (front and rear discs, 12 blades, hub)
  • Support frame (welded stand with hole for mounting on vibration isolators or foundation)
  • Collector (conical, attached to inlet nozzle; overlap between collector and impeller front disc is adjusted by axial movement)
  • Electric motor Electric motor AIR 90 L6 1.5 Power kW 1000 Vol./Min

Position of casings of right-hand (PR) and left-hand (LIV) rotating radial fans VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm, as viewed from the suction side:

a) right-hand rotation
b) left-hand rotation

Position of the housing of right-hand and left-hand rotating radial fans VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm

Note on placement categories based on climatic conditions:

1st category: for operation in the open air (exposure to the combination of climatic factors characteristic of the given macroclimate region);

2nd category: for operation under a canopy or in spaces where temperature and humidity fluctuations do not differ significantly from outdoors, but with relatively free access to external air and protection from direct sunlight and precipitation (e.g., tents, vehicle bodies, trailers, uninsulated metal enclosures, or housings of 1st-category equipment);

3rd category: for operation in enclosed spaces with natural ventilation without artificially regulated climate, where temperature and humidity fluctuations and the influence of dust and sand are significantly lower than outdoors (e.g., insulated metal, stone, concrete, or wooden enclosures without direct exposure to precipitation or sunlight; reduced wind; minimal moisture condensation);

4th category: for operation in spaces with artificially regulated climatic conditions, such as heated or cooled and ventilated industrial premises, air-conditioned or partially air-conditioned halls, and well-ventilated underground spaces (absence of direct sunlight, precipitation, wind, sand, and dust);

5th category: for operation in spaces with elevated humidity (e.g., unheated and unventilated underground spaces including mines, basements, earth-covered structures, ship holds, and other areas where prolonged water presence or frequent moisture condensation on walls and ceilings may occur; textile and hydrometallurgical workshops, etc.).

Specifications
Common
Model
VC 4-75 NZH #6,3
Motor type
AIR, AD
Productivity, м³/h
3190
Pressure, Pa
465
Max. transported air temperature, °C
80
Pollution limits, mg/m3
100
Weight, kg
134
Impeller revs, vol./Min
940
Electric motor AIR 90 L6
Common
Model
AIR 90 L6
Motor type
asynchronous
Kind
general purpose industrial motor
Motor series
AIR
Shaft diameter, mm
24
Voltage, V
220/380
Frequency of the current, Hz
50
Power kW
1.5
Vol./Min
1000
n, vol./Min
920
Climatic performance
UZ
Class of protection, IP
54
Efficiency, %
76
Power factor, cosφ
0,74
Weight, kg
25
Consumed nominal current, In (A)
4,2
Dimension (height of rotation axis), mm
90
Phase
3-phase
The ratio of max. torque to rated power, Mmax/Mn
2,1
The ratio of starting current to the nominal, Istart/In
6
The ratio of starting torque to rated power, Mstart/Mn
2

D/Dn – the diameter ratio fan impeller to the nominal diameter of the impeller. The impellers, which diameters differ from the nominal one, are called co-efficient impellers. The ratio of the diameter of the fan impeller to the nominal diameter of the impeller could be: 0.9, 0.95, 1.05, 1.1.

Fan aerodynamic characteristics with the nominal (standard) diameter of the robotic wheel: D = Dн
Symbols:
Q - air capacity, thousands m3/h;
Pv - total pressure, Pa;
η - efficiency factor;
N - engine power, kW;
U - circumferential wheel speed, m/s;
n - impeller rotation frequency, rpm.

Aerodynamic characteristics for fans
with reduced impeller diameter: D = 0,9 Dn and D = 0,95 Dn,

Fan aerodynamic characteristics Aerodynamic characteristics of fans with reduced impeller diameter

Aerodynamic characteristics for fans
with increased impeller diameter: D = 1,05 Dn and D = 1,1 Dn,

Fan aerodynamic characteristics Aerodynamic characteristics of fans with increased impeller diameter

Overall dimensions of industrial fan VC 4-75 NZh #6.3 w/motor AIR 90 L6 1.5 kW 1000 rpm

Reviews

There are no reviews for this product.

There are no reviews for this product, be the first to leave your review.

Answers & questions
Add your question and we will answer as soon as possible.

No questions about this product, be the first and ask your question.