VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm, execution 1

Low pressure centrifugal fan

Brand: КВЗ
0
All about product
Description
Specification
Aerodynamic Characteristics
Dimensions
Reviews 0
Questions0
In Stock
Product Code: ID9030
88 209₴
Found cheaper?

Low-pressure centrifugal fan of the VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm series for general industrial applications, manufactured according to design scheme No. 1 from AISI 403 stainless steel for aggressive environments.

Productivity, м³/h:11000
Pressure, Pa:1050
Delivery
Nova Poshta Nova Poshta
Delivery (saving 10% of the delivery cost) Delivery (saving 10% of the delivery cost)
Self-delivery Self-delivery
VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm, execution 1
88 209₴
Description

Low-pressure corrosion-resistant centrifugal fan of the VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm series (VR 88-72.1-5.5, VR 80-75-5), made of AISI 403 stainless steel for aggressive environments.

This fan is designed for ventilation or air conditioning systems and other gas mixtures contaminated with aggressive gases and vapors, in which the resistance of stainless steel is higher than the resistance of ordinary quality steel, do not contain fibrous materials, sticky substances, dust, and other solid impurities not more than 100 mg/m3 under moderate (U) climate conditions (placement category 3) and tropical (T) climate (placement category 2).

The centrifugal fan VC 4-75 NZH #6,3 (VR 88-72.1-5.5, VR 80-75-5) consists of the following units, which can be purchased separately:

  • fan VC 4-75 NZH #6,3 (VR 88-72.1-5.5, VR 80-75-5) without electric motor
  • fan impeller VC 4-75 NZH #6,3 (VR 88-72.1-5.5)
  • fan casing (housing) VC 4-75 NZH #6,3 (VR 80-75-5)
  • Electric motor AIR 100 L4

General information about centrifugal fans VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5):

  • Low pressure
  • Single-sided suction
  • Backward-curved blades
  • Number of blades: 12
  • Direction of rotation - right and left
  • Material - stainless steel.

Purpose of centrifugal fans VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5):

The VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm centrifugal fan made of stainless steel is designed for moving air contaminated with aggressive gases and vapors, in which the resistance of stainless steel is higher than that of ordinary quality steel, does not contain sticky substances, fibrous materials, as well as dust and other solid impurities in an amount not exceeding 100 mg/m3.

Centrifugal fans VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5) are used in:

  • air conditioning systems
  • ventilation systems
  • air heating systems
  • for other sanitary and industrial purposes

The centrifugal fan VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5) is operated in moderate climate conditions at ambient temperatures from -40°C to +40°C. The temperature of the transported medium must not exceed 80 °C.

Operating principle of the centrifugal fan VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5):

Air, by transferring energy from the blades of the impeller, enters the fan under the influence of centrifugal force at a 90-degree angle and moves in a radial direction to the snail of the spiral casing. In the snail, moving along the spiral-shaped housing, the air under pressure is directed through the fan outlet.

Completeness of the centrifugal fan VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5):

  • spiral casing,
  • impeller,
  • frame,
  • collector,
  • Electric motor AIR 100 L4

The impeller consists of front and rear discs, 12 sheet blades, and a hub. The frame of the fan is welded. The base has a hole for installation on vibration isolators or a foundation. The electric motor and cover are mounted on the frame. The conical collector for supplying air to the impeller is fixed to the inlet pipe. The overlap between the collector and the front disc of the impeller is adjusted by axial movement of the collector in the inlet pipe.

Position of the casings of radial fans with right (PR) and left (LIV) rotation, view from the suction opening:

Position of the casings of the VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm radial fans for right- and left-hand rotation

Specifications
Common
Model
VC 4-75 NZH #6,3
Motor type
AIRM, AIR, 4AMA
Productivity, м³/h
11000
Pressure, Pa
1050
Max. transported air temperature, °C
80
Pollution limits, mg/m3
100
Weight, kg
143,5
Impeller revs, vol./Min
1425
Maximum efficiency, ηmax (%)
916
Electric motor AIR 100 L4
Common
Model
AIR100L4
Motor type
asynchronous
Kind
general purpose industrial motor
Motor series
AIR
Shaft diameter, mm
28
Voltage, V
220/380
Frequency of the current, Hz
50
Power kW
4.0
Vol./Min
1500
n, vol./Min
1420
Climatic performance
UZ
Class of protection, IP
54
Efficiency, %
82,8
Power factor, cosφ
0,81
Weight, kg
37
Consumed nominal current, In (A)
9,3
Dimension (height of rotation axis), mm
100
Phase
3-phase
The ratio of max. torque to rated power, Mmax/Mn
2,3
The ratio of starting current to the nominal, Istart/In
7
The ratio of starting torque to rated power, Mstart/Mn
2,3
 Aerodynamic characteristics VC 4-75 NZH #6,3

Overall dimensions of industrial fan VC 4-75 NZh #6.3 w/motor AIR 100 L4 4 kW 1500 rpm

Reviews

There are no reviews for this product.

There are no reviews for this product, be the first to leave your review.

Answers & questions
Add your question and we will answer as soon as possible.

No questions about this product, be the first and ask your question.