VC 4-75 #8 w/motor AIR 132 S6 5.5 kW 1000 rpm, execution 1

Low pressure centrifugal fan

Brand: КВЗ
0
All about product
Description
Specification
Technical Specifications
Aerodynamic Characteristics
Dimensions
Reviews 0
Questions0
In Stock
Product Code: ID8634
60 021₴
Found cheaper?

Low-pressure centrifugal fan series VC 4-75 #8 with electric motor Electric motor AIR 132 S6 5.5 Power kW 1000 Vol./Min, manufactured according to the scheme of execution #1. Fan working point: 17000 m3/hour at a pressure of 800 Pa.

Productivity, м³/h:17000
Pressure, Pa:800
Delivery
Nova Poshta Nova Poshta
Delivery (saving 10% of the delivery cost) Delivery (saving 10% of the delivery cost)
Self-delivery Self-delivery
VC 4-75 #8 w/motor AIR 132 S6 5.5 kW 1000 rpm, execution 1
60 021₴
Description

Series VC 4-75 #8 low-pressure centrifugal fan (VR 88-72.1-5.5, VR 80-75-5) with Electric motor AIR 132 S6 5.5 Power kW 1000 Vol./Min electric motor, execution scheme № 5 with V-belt drive, manufactured from dissimilar materials for explosive atmospheres.

Intended Application:

This fan is intended for ventilation or air-conditioning systems handling gas–steam–air explosive mixtures of the 1st and 2nd categories of groups T1, T2, T3 according to the classification of the “Rules for Electrical Installations” (PVE), which do not cause accelerated corrosion of the materials in the flow parts of the fans. These mixtures must not exceed a temperature of 80 °C, and the content of fibrous materials, sticky substances, dust, and other solid impurities must not exceed 100 mg/m³ under moderate (U) climate (placement category 3) and tropical (T) climate (placement category 2) conditions in accordance with DSTU 15150. Ambient temperature is permitted from −40 °C to +40 °C (+40 °C when equipped with tropical-design electric motors).

Housing and Impeller Blade Material:

The housing and impeller blades of the explosion-proof fans are manufactured from material pairs (steel–brass or steel–aluminum) that form a non-sparking combination under frictional conditions, in accordance with DSTU 22782.0-81.

Configuration and Modular Components (available separately):

  • Fan housing VC 4-75 #8 (VR 88-72.1-5.5, VR 80-75-5) without electric motor
  • Impeller wheel of fan VC 4-75 #8 (VR 88-72.1-5.5)
  • Fan casing (scroll) VC 4-75 #8 (VR 80-75-5)
  • Electric motor Electric motor AIR 132 S6 5.5 Power kW 1000 Vol./Min for fan VC 4-75 #8

General Characteristics of Series VC 4-75 #8 Centrifugal Fans with Electric motor AIR 132 S6 5.5 Power kW 1000 Vol./Min, Manufactured from Dissimilar Metals:

  • Low pressure
  • Single-sided suction
  • Backward-curved blades
  • Number of blades: 12
  • Direction of rotation: right and left
  • Execution scheme: № 5 with V-belt drive
  • Manufactured in accordance with TU U 28.2-24881057-003:2023
  • Construction material: dissimilar metals

Applications of Series VC 4-75 #8 w/motor AIR 132 S6 5.5 kW 1000 rpm Fans (VR 88-72.1-5.5, VR 80-75-5):

  • Air-conditioning systems
  • Ventilation systems
  • Air-heating systems
  • Other sanitary and industrial purposes

Operating Conditions:

Series VC 4-75 #8 w/motor AIR 132 S6 5.5 kW 1000 rpm centrifugal fans operate under moderate climate conditions at ambient temperatures from −40 °C to +40 °C. The conveyed medium must not exceed 80 °C.

Principle of Operation:

Air, by means of energy imparted by the impeller blades, enters the fan under centrifugal force at a 90° angle and is directed radially into the scroll-shaped casing. Within the casing, the pressurized air follows a spiral path and is discharged through the fan outlet.

Delivery Set of Series VC 4-75 #8 Fans Made of Dissimilar Metals:

  • Scroll-shaped casing
  • Impeller wheel (front and rear discs, 12 sheet blades, and hub)
  • Support frame (welded stand with hole for mounting on vibration isolators or foundation)
  • Collector (conical, attached to the inlet nozzle; overlap between collector and impeller front disc is adjusted by axial movement within the inlet nozzle)
  • Electric motor Electric motor AIR 132 S6 5.5 Power kW 1000 Vol./Min

Position of Radial Fan Housings for Right (PR) and Left (LIV) Rotation, Viewed from the Suction Side:

  • Right rotation
  • Left rotation

Position of the housing of right-hand and left-hand rotating radial fans VC 4-75 #8 w/motor AIR 132 S6 5.5 kW 1000 rpm


Note on Placement Categories Based on Climatic Conditions:

1st category: operation in the open air (influence of combined climatic factors characteristic of the given macroclimate region);

2nd category: operation under a canopy or in volumes where temperature and humidity fluctuations do not differ significantly from those outdoors and there is relatively free access to external air, e.g., tents, vehicle bodies, trailers, uninsulated metal enclosures, and in enclosures of 1st category products (absence of direct solar radiation and precipitation);

3rd category: operation in enclosed volumes with natural ventilation without artificially regulated climatic conditions, where temperature and humidity fluctuations and the influence of dust and sand are significantly less than outdoors (e.g., insulated metal, stone, concrete, wooden enclosures; absence of precipitation and direct solar radiation; significant reduction in wind; reduced or absent diffused solar radiation and condensation);

4th category: operation in spaces with artificially regulated climatic conditions, such as closed heated or cooled and ventilated production premises, conditioned or partially conditioned air environments, and well-ventilated underground spaces (absence of direct solar radiation, precipitation, wind, sand, and dust; absence or significant reduction of diffused solar radiation and condensation);

5th category: operation in spaces with elevated humidity (e.g., unheated and unventilated underground spaces including mines, basements, ground burials, ship holds, and other areas where water may persist or frequent condensation may occur on walls and ceilings; e.g., certain holds, textile and hydrometallurgical production areas).

Specifications
Common
Model
VC 4-75 #8
Motor type
5AMU, AD, AIRM
Productivity, м³/h
17000
Pressure, Pa
800
Max. transported air temperature, °C
80
Pollution limits, mg/m3
100
Weight, kg
306
Impeller revs, vol./Min
960
Electric motor AIR 132 S6
Common
Model
AIR 132 S6
Motor type
asynchronous
Kind
general purpose industrial motor
Motor series
AIR
Shaft diameter, mm
38
Voltage, V
220/380
Frequency of the current, Hz
50
Power kW
5.5
Vol./Min
1000
n, vol./Min
955
Climatic performance
UZ
Class of protection, IP
54
Efficiency, %
82,8
Power factor, cosφ
0,78
Weight, kg
75
Consumed nominal current, In (A)
13
Dimension (height of rotation axis), mm
132
Phase
3-phase
The ratio of max. torque to rated power, Mmax/Mn
2,1
The ratio of starting current to the nominal, Istart/In
6,3
The ratio of starting torque to rated power, Mstart/Mn
2,1



D/Dn – the diameter ratio fan impeller to the nominal diameter of the impeller. The impellers, which diameters differ from the nominal one, are called co-efficient impellers. The ratio of the diameter of the fan impeller to the nominal diameter of the impeller could be: 0.9, 0.95, 1.05, 1.1.

Fan aerodynamic characteristics with the nominal (standard) diameter of the robotic wheel: D = Dн
Symbols:
Q- air capacity, thousands m3/h;
Pv- total pressure, Pa;
η- efficiency factor;
N- engine power, kW;
U- circumferential wheel speed, m/s;
n- impeller rotation frequency, rpm.

Aerodynamic characteristics for fans
with reduced impeller diameter: D = 0,9 Dn and D = 0,95 Dn,

Fan aerodynamic characteristicsAerodynamic characteristics of fans with reduced impeller diameter

Aerodynamic characteristics for fans
with increased impeller diameter: D = 1,05 Dn and D = 1,1 Dn,

Fan aerodynamic characteristicsAerodynamic characteristics of fans with increased impeller diameter

Overall dimensions of industrial fan VC 4-75 #8 w/motor AIR 132 S6 5.5 kW 1000 rpm

Reviews

There are no reviews for this product.

There are no reviews for this product, be the first to leave your review.

Answers & questions
Add your question and we will answer as soon as possible.

No questions about this product, be the first and ask your question.