VC 4-75 VZ #4 w/motor 4VR 132 M2 11 kW 3000 rpm, execution 1

Low pressure centrifugal fan

Brand: КВЗ
0
All about product
Description
Specification
Aerodynamic Characteristics
Dimensions
Reviews 0
Questions0
In Stock
Product Code: ID11127
49 627₴
Found cheaper?

Low-pressure centrifugal fan series VC 4-75 #4 with electric motor Electric motor 4VR 132 M2 11.0 Power kW 3000 Vol./Min, manufactured according to the scheme of execution #1 of dissimilar materials for explosive environments.
Fan working point: 10000 m3/hour at a pressure of 1800 Pa.

Productivity, м³/h:10000
Pressure, Pa:1800
Delivery
Nova Poshta Nova Poshta
Delivery (saving 10% of the delivery cost) Delivery (saving 10% of the delivery cost)
Self-delivery Self-delivery
VC 4-75 VZ #4 w/motor 4VR 132 M2 11 kW 3000 rpm, execution 1
49 627₴
Description

The low-pressure centrifugal fan of the VC 4-75 #4 series (VR 88-72.1-5.5, VR 80-75-5) with the electric motor Electric motor 4VR 132 M2 11.0 Power kW 3000 Vol./Min is manufactured from dissimilar materials for use in explosive environments.

This fan is intended for use in ventilation or air conditioning systems handling explosive gas-vapor-air mixtures of categories 1 and 2, groups T1, T2, T3 according to the classification of the "Rules for Electrical Installations" (PUE). These mixtures must not cause accelerated corrosion of the materials in the airflow section of the fan. The temperature of these mixtures must not exceed 80 °C, and the content of fibrous materials, sticky substances, dust, and other solid impurities must not exceed 100 mg/m³ under moderate climate conditions (category 3 placement) and tropical climate conditions (category 2 placement), in accordance with DSTU 15150. The permissible ambient temperature ranges from -40°C to +40°C (+40°C when equipped with tropical-design electric motors).

The housing and impeller blades of explosion-proof fans are made of material pairs (Steel-Brass or Steel-Aluminum) that are not hazardous in terms of ignition from friction sparks, according to DSTU 22782.0-81.

The centrifugal fan VC 4-75 #4 (VR 88-72.1-5.5, VR 80-75-5) consists of the following units, which can be purchased separately:

  • Fan VC 4-75 #4 (VR 88-72.1-5.5, VR 80-75-5) without electric motor
  • Fan impeller VC 4-75 #4 (VR 88-72.1-5.5)
  • Fan casing (housing) VC 4-75 #4 (VR 80-75-5)
  • Electric motor Electric motor 4VR 132 M2 11.0 Power kW 3000 Vol./Min for fan VC 4-75 #4

General information about centrifugal fans VC 4-75 #4 (VR 88-72.1-5.5, VR 80-75-5) with electric motor Electric motor 4VR 132 M2 11.0 Power kW 3000 Vol./Min made of dissimilar metals:

  • Low pressure
  • Single-side suction
  • Backward-curved blades
  • 12 blades
  • Rotation direction – right and left
  • Fans are manufactured in accordance with TU U 28.2-24881057-003:2023
  • Material – dissimilar metals

Application of centrifugal fans VC 4-75 VZ #4 w/motor 4VR 132 M2 11 kW 3000 rpm (VR 88-72.1-5.5, VR 80-75-5):

This fan is designed for use in ventilation or air conditioning systems handling explosive gas-vapor-air mixtures of categories 1 and 2, groups T1, T2, T3 according to the classification of the "Rules for Electrical Installations" (PUE). These mixtures must not cause accelerated corrosion of the materials in the airflow section of the fan. The mixture temperature must not exceed 80 °C, and the content of fibrous materials, sticky substances, dust, and other solid impurities must not exceed 100 mg/m³ under moderate climate conditions (category 3 placement) and tropical climate conditions (category 2 placement), according to GOST 15150. The permissible ambient temperature ranges from -40°C to +40°C (+40°C when equipped with tropical-design electric motors).

Centrifugal fans VC 4-75 VZ #4 w/motor 4VR 132 M2 11 kW 3000 rpm (VR 88-72.1-5.5, VR 80-75-5) are used in:

  • Air conditioning systems
  • Ventilation systems
  • Air heating systems
  • Other sanitary and industrial purposes

The centrifugal fan VC 4-75 VZ #4 w/motor 4VR 132 M2 11 kW 3000 rpm (VR 88-72.1-5.5, VR 80-75-5) operates under moderate climate conditions at ambient temperatures from -40°C to +40°C. The temperature of the handled medium must not exceed 80 °C.

Operating principle of the centrifugal fan VC 4-75 VZ #4 w/motor 4VR 132 M2 11 kW 3000 rpm (VR 88-72.1-5.5, VR 80-75-5):

Air, by receiving energy from the impeller blades, enters the fan under the influence of centrifugal force at a 90-degree angle and is directed radially toward the spiral-shaped scroll casing. Inside the scroll, the air moves under pressure through the spiral-shaped casing and is directed to the fan outlet.

Fan configuration for the centrifugal fan VC 4-75 #4 made of dissimilar metals:

The fan VC 4-75 #4 (VR 88-72.1-5.5, VR 80-75-5) with the electric motor Electric motor 4VR 132 M2 11.0 Power kW 3000 Vol./Min consists of the following main components:

  • Spiral casing
  • Impeller
  • Base frame
  • Collector
  • Electric motor Electric motor 4VR 132 M2 11.0 Power kW 3000 Vol./Min

The impeller consists of a front and rear disk, 12 sheet metal blades, and a hub.

The base frame of the fan is welded. The base has an opening for installation on vibration isolators or a foundation. The electric motor and protective cover are mounted on the base frame.

The conical collector for guiding air to the impeller is mounted on the inlet nozzle. The overlap between the collector and the front disk of the impeller is adjusted by axially moving the collector inside the inlet nozzle.

Orientation of the radial fan housings with right-hand (RH) and left-hand (LH) rotation, as viewed from the suction side:

  • a) right-hand rotation
  • b) left-hand rotation

Position of the housing of right-hand and left-hand rotating radial fans VC 4-75 VZ #4 w/motor 4VR 132 M2 11 kW 3000 rpm

Note on placement categories depending on climatic conditions:

Category 1: For outdoor use (exposed to the full range of climatic factors characteristic of the given macroclimatic region).

Category 2: For use under shelter or in premises where temperature and humidity variations are not significantly different from those outdoors, and where external air has relatively free access, such as in tents, truck bodies, trailers, uninsulated metal enclosures, or in the enclosure of equipment rated for Category 1 (without direct exposure to sunlight and precipitation).

Category 3: For use indoors with natural ventilation but without artificially controlled climatic conditions, where temperature and humidity fluctuations, and exposure to sand and dust, are significantly lower than outdoors, such as in insulated metal, stone, concrete, or wooden buildings (protected from precipitation, direct sunlight, significantly reduced wind, and minimized or absent scattered solar radiation and moisture condensation).

Category 4: For use indoors with artificially regulated climatic conditions, such as heated, cooled, or ventilated rooms, or other well-ventilated underground premises (protected from direct sunlight, precipitation, wind, external sand and dust, with minimized or absent exposure to scattered solar radiation and moisture condensation).

Category 5: For use in areas with high humidity (e.g., unheated and unventilated underground spaces such as mines, basements, soil environments, ship compartments, or other areas with possible long-term water presence or frequent condensation on walls and ceilings, such as certain holds or workshops in textile or hydrometallurgical production).

Specifications
Common
Model
VC 4-75 #4
Productivity, м³/h
10000
Pressure, Pa
1800
Max. transported air temperature, °C
80
Pollution limits, mg/m3
100
Electric motor 4VR 132 M2
Common
Model
4VR 132 M2
Motor type
asynchronous
Kind
explosion-proof
Motor series
4VR
Shaft diameter, mm
38
Voltage, V
220/380
Frequency of the current, Hz
50
Power kW
11.0
Vol./Min
3000
n, vol./Min
2910
Climatic performance
UZ
Class of protection, IP
54
Efficiency, %
87,5
Power factor, cosφ
0,90
Weight, kg
87,2
Consumed nominal current, In (A)
21,8
Dimension (height of rotation axis), mm
132
Phase
3-phase
The ratio of max. torque to rated power, Mmax/Mn
1,6
The ratio of starting current to the nominal, Istart/In
7,5
The ratio of starting torque to rated power, Mstart/Mn
2,2

D/Dn – the diameter ratio fan impeller to the nominal diameter of the impeller. The impellers, which diameters differ from the nominal one, are called co-efficient impellers. The ratio of the diameter of the fan impeller to the nominal diameter of the impeller could be: 0.9, 0.95, 1.05, 1.1.

Fan aerodynamic characteristics with the nominal (standard) diameter of the robotic wheel: D = Dн
Symbols:
Q - air capacity, thousands m3/h;
Pv - total pressure, Pa;
η - efficiency factor;
N - engine power, kW;
U - circumferential wheel speed, m/s;
n - impeller rotation frequency, rpm.

 

Aerodynamic characteristics for fans
with reduced impeller diameter: D = 0,9 Dn and D = 0,95 Dn,

Fan aerodynamic characteristics Aerodynamic characteristics of fans with reduced impeller diameter

 

 

Aerodynamic characteristics for fans
with increased impeller diameter: D = 1,05 Dn and D = 1,1 Dn,

Fan aerodynamic characteristics Aerodynamic characteristics of fans with increased impeller diameter

Overall dimensions of industrial fan VC 4-75 VZ #4 w/motor 4VR 132 M2 11 kW 3000 rpm