We work! Large selection of equipment for ventilation systems.
Catalog
Client
(044) 238-24-81
Our location:
6, Predprinimatelska str., Brovary, Kyiv region
Phones:
Working hours
  • shop
  • from 7:00 to 20:00 Mon - Fri
  • warehouse and accounting
  • Mon - Fri from 8:00 to 17:00
  • without a lunch break
E-mail
We are on social networks
Go to contacts
0 0
Catalog
Main page
Wishlist
0
Compare
0
Contacts

VC 4-75 VZ #2.5 w/motor 4VR 71 B4 0.75 kW 1500 rpm, execution 1

Low pressure centrifugal fan

Brand: КВЗ
0
All about product
Description
Specification
Aerodynamic Characteristics
Dimensions
Reviews 0
Questions0
In Stock
Product Code: ID11050
17 161₴
Found cheaper?

Low-pressure centrifugal fan series VC 4-75 #2,5 
With electric motor Electric motor 4VR 71 B4 0.75 Power kW 1500 Vol./Min
Manufactured according to the scheme of execution #1 of dissimilar materials for explosive environments.
Fan working point: 710 m3/hour at a pressure of 155 Pa.

Productivity, м³/h:710
Pressure, Pa:155
Delivery
Nova Poshta Nova Poshta
Delivery (saving 10% of the delivery cost) Delivery (saving 10% of the delivery cost)
Self-delivery Self-delivery
VC 4-75 VZ #2.5 w/motor 4VR 71 B4 0.75 kW 1500 rpm, execution 1
17 161₴
Description

The centrifugal low-pressure fan of the VC 4-75 #2,5 series (VR 88-72.1-5.5, VR 80-75-5) with an Electric motor 4VR 71 B4 0.75 Power kW 1500 Vol./Min electric motor is manufactured from dissimilar metals for explosive environments.

This fan is intended for ventilation or air conditioning systems handling explosive gas-air mixtures of the 1st and 2nd categories, groups T1, T2, and T3 according to the "Rules for Electrical Installation" (PVE) classification, which do not cause accelerated corrosion of the fan's airflow parts. These mixtures must not exceed a temperature of 620 °C, and the content of fibrous materials, sticky substances, dust, and other solid impurities must not exceed 100 mg/m³ under moderate (U) climate conditions (placement category 3) and tropical (T) climate conditions (placement category 2) according to DSTU 15150. The permissible ambient temperature range is from -40°C to +40°C (+40°C when equipped with tropical-design electric motors).

The casing and impeller blades of explosion-proof fans are made from material pairs (Steel-Brass or Steel-Aluminum) that are safe from ignition by friction sparks according to DSTU 22782.0-81.

The centrifugal fan VC 4-75 #2,5 (VR 88-72.1-5.5, VR 80-75-5) consists of the following assemblies, available separately:

  • VC 4-75 #2,5 (VR 88-72.1-5.5, VR 80-75-5) fan without electric motor
  • Fan impeller VC 4-75 #2,5 (VR 88-72.1-5.5)
  • Fan casing (scroll housing) VC 4-75 #2,5 (VR 80-75-5)
  • Electric motor Electric motor 4VR 71 B4 0.75 Power kW 1500 Vol./Min for VC 4-75 #2,5 fan

General information about centrifugal fans VC 4-75 #2,5 (VR 88-72.1-5.5, VR 80-75-5) with an Electric motor 4VR 71 B4 0.75 Power kW 1500 Vol./Min electric motor made of dissimilar metals:

  • Low-pressure
  • Single-sided suction
  • Backward-curved blades
  • 12 blades
  • Right-hand and left-hand rotation available
  • Fans are manufactured according to TU U 28.2-24881057-003:2023
  • Material: dissimilar metals

Purpose of centrifugal fans VC 4-75 VZ #2.5 w/motor 4VR 71 B4 0.75 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5):
The fan is designed for ventilation or air conditioning systems transporting explosive gas-air mixtures of the 1st and 2nd categories, groups T1, T2, and T3 as per the "Rules for Electrical Installation" (PVE), which do not cause accelerated corrosion of the airflow parts. The temperature of the transported medium should not exceed 620 °C, and the content of fibrous materials, sticky substances, dust, and other solid impurities should not exceed 100 mg/m³ under moderate (U) climate conditions (placement category 3) and tropical (T) climate conditions (placement category 2) according to GOST 15150. The allowable ambient temperature range is -40 °C to +40 °C (+40 °C with tropical-version electric motors).

Centrifugal fans VC 4-75 VZ #2.5 w/motor 4VR 71 B4 0.75 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5) are used:

  • In air conditioning systems
  • In ventilation systems
  • In air heating systems
  • For other sanitary and industrial purposes

The centrifugal fan VC 4-75 VZ #2.5 w/motor 4VR 71 B4 0.75 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5) operates under moderate climate conditions with an ambient temperature range of -40 °C to +40 °C. The transported medium’s temperature must not exceed 620 °C.

Operating principle of the centrifugal fan VC 4-75 VZ #2.5 w/motor 4VR 71 B4 0.75 kW 1500 rpm (VR 88-72.1-5.5, VR 80-75-5):
Air, gaining energy from the impeller blades, enters the fan under the influence of centrifugal force at a 90-degree angle and is directed radially into the spiral-shaped scroll casing. As the air moves through the spiral casing, it is pressurized and directed out through the fan's outlet.

Fan assembly components of VC 4-75 #2,5 centrifugal fan made of dissimilar metals:
The VC 4-75 #2,5 (VR 88-72.1-5.5, VR 80-75-5) fan with the Electric motor 4VR 71 B4 0.75 Power kW 1500 Vol./Min electric motor includes:

  • Scroll casing
  • Impeller
  • Base frame
  • Collector
  • Electric motor Electric motor 4VR 71 B4 0.75 Power kW 1500 Vol./Min

The impeller consists of a front and rear disc, 12 sheet blades, and a hub.

The fan's base frame is welded. The base features an opening for installation on vibration isolators or a foundation. The electric motor and casing are mounted onto the base.

The conical collector for guiding air to the impeller is mounted on the inlet duct. The overlap between the collector and the impeller’s front disc can be adjusted by axial movement of the collector within the inlet duct.

Casing position of right- and left-hand rotation radial fans (view from the suction side):

a) right-hand rotation
b) left-hand rotation
Mounting hole layout for vibration isolators VC 4-75 VZ #2.5 w/motor 4VR 71 B4 0.75 kW 1500 rpm

Note on placement categories depending on climatic conditions:

  • Category 1: For operation in open air conditions (exposure to the combination of climatic factors typical for a given macroclimatic region).
  • Category 2: For operation under a canopy or inside spaces (volumes) where temperature and humidity fluctuations are not significantly different from those in the open air, and there is relatively free access to outside air. Examples include tents, vehicle bodies, trailers, metal shelters without thermal insulation, and the casing of a complete product classified as category 1 (without direct exposure to solar radiation and atmospheric precipitation).
  • Category 3: For operation in enclosed spaces (volumes) with natural ventilation without artificially controlled climatic conditions, where fluctuations in temperature and humidity, as well as the influence of sand and dust, are significantly less than in the open air. Examples include insulated metal buildings, stone, concrete, and wooden structures.
  • Category 4: For operation in premises (volumes) with artificially regulated climatic conditions, such as closed heated, cooled, or ventilated production facilities; premises with conditioned or partially conditioned air; and other well-ventilated underground spaces.
  • Category 5: For operation in spaces (volumes) with high humidity, such as unheated and unventilated underground premises, including mines, basements, soil-embedded spaces, certain ship compartments, and other spaces prone to prolonged water presence or frequent condensation of moisture on walls and ceilings.
Specifications
Common
Model
VC 4-75 #2,5
Productivity, м³/h
710
Pressure, Pa
155
Max. transported air temperature, °C
620
Pollution limits, mg/m3
100
Electric motor 4VR 71 B4
Common
Model
4VR 71 B4
Motor type
asynchronous
Kind
explosion-proof
Motor series
4VR
Shaft diameter, mm
19
Voltage, V
220/380
Frequency of the current, Hz
50
Power kW
0.75
Vol./Min
1500
n, vol./Min
1350
Climatic performance
UZ
Class of protection, IP
54
Efficiency, %
72,0
Power factor, cosφ
0,77
Weight, kg
15,6
Consumed nominal current, In (A)
2,2
Dimension (height of rotation axis), mm
71
Phase
3-phase
The ratio of max. torque to rated power, Mmax/Mn
2,5
The ratio of starting current to the nominal, Istart/In
5,0
The ratio of starting torque to rated power, Mstart/Mn
2,6

D/Dn – the diameter ratio of the fan impeller to the nominal diameter of the impeller. The impellers, which diameters differ from the nominal one, are called co-efficient impellers. The ratio of the diameter of the fan impeller to the nominal diameter of the impeller could be: 0.9, 0.95, 1.05, 1.1.

Fan aerodynamic characteristics with the nominal (standard) diameter of the robotic wheel: D = Dn
Symbols:
Q- air capacity, thousands m³/h
Pv- total pressure, Pa
η- efficiency factor
N- engine power, kW
U- circumferential wheel speed, m/s
n- impeller rotation frequency, rpm

Aerodynamic characteristics for fans with reduced impeller diameter: D = 0.9 Dn and D = 0.95 Dn

Fan aerodynamic characteristics Aerodynamic characteristics of fans with reduced impeller diameter

Aerodynamic characteristics for fans with increased impeller diameter: D = 1.05 Dn and D = 1.1 Dn

Fan aerodynamic characteristics Aerodynamic characteristics of fans with increased impeller diameter

Overall dimensions of industrial fan VC 4-75 VZ #2.5 w/motor 4VR 71 B4 0.75 kW 1500 rpm