Low-pressure centrifugal fan series VC 4-75 #2,5
With electric motor Electric motor 4VR 71 B2 1.1 Power kW 3000 Vol./Min
Manufactured according to the scheme of execution #1 of dissimilar materials for explosive environments.
Fan working point: 1420 m3/hour at a pressure of 620 Pa.
VC 4-75 VZ #2.5 w/motor 4VR 71 B2 1.1 kW 3000 rpm, execution 1
Low pressure centrifugal fan



The centrifugal low-pressure fan of the VC 4-75 #2,5 series (VR 88-72.1-5.5, VR 80-75-5) with an Electric motor 4VR 71 B2 1.1 Power kW 3000 Vol./Min electric motor is manufactured from dissimilar metals for explosive environments.
This fan is intended for ventilation or air conditioning systems handling explosive gas-air mixtures of the 1st and 2nd categories, groups T1, T2, and T3 according to the "Rules for Electrical Installation" (PVE) classification, which do not cause accelerated corrosion of the fan's airflow parts. These mixtures must not exceed a temperature of 150 °C, and the content of fibrous materials, sticky substances, dust, and other solid impurities must not exceed 100 mg/m³ under moderate (U) climate conditions (placement category 3) and tropical (T) climate conditions (placement category 2) according to DSTU 15150. The permissible ambient temperature range is from -40°C to +40°C (+40°C when equipped with tropical-design electric motors).
The casing and impeller blades of explosion-proof fans are made from material pairs (Steel-Brass or Steel-Aluminum) that are safe from ignition by friction sparks according to DSTU 22782.0-81.
The centrifugal fan VC 4-75 #2,5 (VR 88-72.1-5.5, VR 80-75-5) consists of the following assemblies, available separately:
- VC 4-75 #2,5 (VR 88-72.1-5.5, VR 80-75-5) fan without electric motor
- Fan impeller VC 4-75 #2,5 (VR 88-72.1-5.5)
- Fan casing (scroll housing) VC 4-75 #2,5 (VR 80-75-5)
- Electric motor Electric motor 4VR 71 B2 1.1 Power kW 3000 Vol./Min for VC 4-75 #2,5 fan
General information about centrifugal fans VC 4-75 #2,5 (VR 88-72.1-5.5, VR 80-75-5) with an Electric motor 4VR 71 B2 1.1 Power kW 3000 Vol./Min electric motor made of dissimilar metals:
- Low-pressure
- Single-sided suction
- Backward-curved blades
- 12 blades
- Right-hand and left-hand rotation available
- Fans are manufactured according to TU U 28.2-24881057-003:2023
- Material: dissimilar metals
Purpose of centrifugal fans VC 4-75 VZ #2.5 w/motor 4VR 71 B2 1.1 kW 3000 rpm (VR 88-72.1-5.5, VR 80-75-5):
The fan is designed for ventilation or air conditioning systems transporting explosive gas-air mixtures of the 1st and 2nd categories, groups T1, T2, and T3 as per the "Rules for Electrical Installation" (PVE), which do not cause accelerated corrosion of the airflow parts. The temperature of the transported medium should not exceed 150 °C, and the content of fibrous materials, sticky substances, dust, and other solid impurities should not exceed 100 mg/m³ under moderate (U) climate conditions (placement category 3) and tropical (T) climate conditions (placement category 2) according to GOST 15150. The allowable ambient temperature range is -40 °C to +40 °C (+40 °C with tropical-version electric motors).
Centrifugal fans VC 4-75 VZ #2.5 w/motor 4VR 71 B2 1.1 kW 3000 rpm (VR 88-72.1-5.5, VR 80-75-5) are used:
- In air conditioning systems
- In ventilation systems
- In air heating systems
- For other sanitary and industrial purposes
The centrifugal fan VC 4-75 VZ #2.5 w/motor 4VR 71 B2 1.1 kW 3000 rpm (VR 88-72.1-5.5, VR 80-75-5) operates under moderate climate conditions with an ambient temperature range of -40 °C to +40 °C. The transported medium’s temperature must not exceed 150 °C.
Operating principle of the centrifugal fan VC 4-75 VZ #2.5 w/motor 4VR 71 B2 1.1 kW 3000 rpm (VR 88-72.1-5.5, VR 80-75-5):
Air, gaining energy from the impeller blades, enters the fan under the influence of centrifugal force at a 90-degree angle and is directed radially into the spiral-shaped scroll casing. As the air moves through the spiral casing, it is pressurized and directed out through the fan's outlet.
Fan assembly components of VC 4-75 #2,5 centrifugal fan made of dissimilar metals:
The VC 4-75 #2,5 (VR 88-72.1-5.5, VR 80-75-5) fan with the Electric motor 4VR 71 B2 1.1 Power kW 3000 Vol./Min electric motor includes:
- Scroll casing
- Impeller
- Base frame
- Collector
- Electric motor Electric motor 4VR 71 B2 1.1 Power kW 3000 Vol./Min
The impeller consists of a front and rear disc, 12 sheet blades, and a hub.
The fan's base frame is welded. The base features an opening for installation on vibration isolators or a foundation. The electric motor and casing are mounted onto the base.
The conical collector for guiding air to the impeller is mounted on the inlet duct. The overlap between the collector and the impeller’s front disc can be adjusted by axial movement of the collector within the inlet duct.
Casing position of right- and left-hand rotation radial fans (view from the suction side):

D/Dn – the diameter ratio of the fan impeller to the nominal diameter of the impeller. The impellers, which diameters differ from the nominal one, are called co-efficient impellers. The ratio of the diameter of the fan impeller to the nominal diameter of the impeller could be: 0.9, 0.95, 1.05, 1.1.
![]() |
|
Aerodynamic characteristics for fans with reduced impeller diameter: D = 0.9 Dn and D = 0.95 Dn
![]() |
![]() |
Aerodynamic characteristics for fans with increased impeller diameter: D = 1.05 Dn and D = 1.1 Dn
![]() |
![]() |
There are no reviews for this product.
There are no reviews for this product, be the first to leave your review.
No questions about this product, be the first and ask your question.
Note on placement categories depending on climatic conditions: