VC 4-75 #10 w/motor AIR 112 MB6 4 kW 1000 rpm, execution 5

Low pressure centrifugal fan

Brand: КВЗ
0
All about product
Description
Specification
Aerodynamic Characteristics
Reviews 0
Questions0
In Stock
Product Code: ID8712
142 174₴
Found cheaper?

Low-pressure centrifugal fan series VC 4-75 #10 with electric motor Electric motor AIR 112 MV6 4.0 Power kW 1000 Vol./Min for general industrial use, made by execution scheme #5 using the belt transmission made of carbon steel. Fan working point: 20000 m3/hour at a pressure of 500 Pa.

Productivity, м³/h:20000
Pressure, Pa:500
Delivery
Nova Poshta Nova Poshta
Delivery (saving 10% of the delivery cost) Delivery (saving 10% of the delivery cost)
Self-delivery Self-delivery
VC 4-75 #10 w/motor AIR 112 MB6 4 kW 1000 rpm, execution 5
142 174₴
Description

Series VC 4-75 #10 low-pressure centrifugal fan (VR 88-72.1-5.5, VR 80-75-5) with electric motor Electric motor AIR 112 MV6 4.0 Power kW 1000 Vol./Min, general-purpose design, execution scheme № 5 with V-belt drive, made of carbon steel.

Intended Application:

This fan is designed for ventilation or air-conditioning systems and other gas mixtures whose corrosiveness to carbon steel does not exceed that of air at up to 80 °C, and which contain no fibrous materials, sticky substances, dust, or other solid impurities in excess of 100 mg/m³ under moderate (U) climate (placement category 3) and tropical (T) climate (placement category 2) conditions in accordance with DSTU 15150.

Modular Components (available separately):

  • Fan assembly VC 4-75 #10 without electric motor
  • Impeller wheel VC 4-75 #10 (VR 88-72.1-5.5)
  • Scroll casing VC 4-75 #10 (VR 80-75-5)
  • Electric motor Electric motor AIR 112 MV6 4.0 Power kW 1000 Vol./Min for fan VC 4-75 #10

General Characteristics of Series VC 4-75 #10 w/motor AIR 112 MB6 4 kW 1000 rpm (VR 88-72.1-5.5, VR 80-75-5):

  • Low pressure
  • Single-sided suction
  • Backward-curved blades
  • Number of blades: 12
  • Direction of rotation: right and left
  • Execution scheme: № 5 (V-belt drive with V-belts and drive/driven pulleys)
  • Manufactured according to TU U 28.2-24881057-003:2023

Applications:

  • Air-conditioning systems
  • Ventilation systems
  • Air-heating systems
  • Other sanitary and industrial purposes

Operating Conditions:

Operates in moderate climate conditions at ambient temperatures from −40 °C to +40 °C. The temperature of the conveyed medium must not exceed 80 °C.

Principle of Operation:

Air, by energy imparted by the impeller blades, enters the fan under centrifugal force at a 90° angle and is directed radially into the scroll-shaped casing; within the casing, the pressurized air follows a spiral path and is discharged through the fan outlet.

Delivery Set of Series VC 4-75 #10 w/motor AIR 112 MB6 4 kW 1000 rpm Fans:

  • Scroll-shaped casing
  • Impeller wheel (front/rear discs, 12 blades, hub)
  • Support frame (welded stand with hole for mounting on vibration isolators or foundation)
  • Collector (conical, attached to inlet nozzle; overlap adjusted by axial movement)
  • Electric motor Electric motor AIR 112 MV6 4.0 Power kW 1000 Vol./Min

Position of Radial Fan Housing (viewed from suction side):

  • Right rotation (PR)
  • Left rotation (LIV)

Position of the housing of right-hand and left-hand rotating radial fans VC 4-75 #10 w/motor AIR 112 MB6 4 kW 1000 rpm

Placement Categories (climatic conditions):

  1. 1st category: open air (exposed to natural climatic factors).
  2. 2nd category: under a canopy or semi-enclosed spaces with conditions close to outdoors but without direct precipitation or sunlight.
  3. 3rd category: enclosed spaces with natural ventilation and minor temperature/humidity fluctuations; low dust and sand levels.
  4. 4th category: artificially regulated climate (heated/cooled and ventilated industrial premises or well-ventilated underground spaces).
  5. 5th category: high-humidity spaces (e.g., unheated/uneventilated basements, mines, ship holds; areas with frequent condensation).
Specifications
Common
Model
VC 4-75 #10
Motor type
AD, AIRU, 5AM, AK
Productivity, м³/h
20000
Pressure, Pa
500
Max. transported air temperature, °C
80
Pollution limits, mg/m3
100
Weight, kg
535
Impeller revs, vol./Min
610
Maximum efficiency, ηmax (%)
2000
Electric motor AIR 112 MV6
Common
Model
AIR 112 MB6
Motor type
asynchronous
Kind
general purpose industrial motor
Motor series
AIR
Shaft diameter, mm
32
Voltage, V
220/380
Frequency of the current, Hz
50
Power kW
4.0
Vol./Min
1000
n, vol./Min
935
Climatic performance
UZ
Class of protection, IP
54
Efficiency, %
80,7
Power factor, cosφ
0,77
Weight, kg
50
Consumed nominal current, In (A)
10
Dimension (height of rotation axis), mm
112
Phase
3-phase
The ratio of max. torque to rated power, Mmax/Mn
2,1
The ratio of starting current to the nominal, Istart/In
5,7
The ratio of starting torque to rated power, Mstart/Mn
2,1

D/Dn – the diameter ratio fan impeller to the nominal diameter of the impeller. The impellers, which diameters differ from the nominal one, are called co-efficient impellers. The ratio of the diameter of the fan impeller to the nominal diameter of the impeller could be: 0.9, 0.95, 1.05, 1.1.

Fan aerodynamic characteristics with the nominal (standard) diameter of the robotic wheel: D = Dн
Symbols:
Q - air capacity, thousands m3/h;
Pv - total pressure, Pa;
η - efficiency factor;
N - engine power, kW;
U - circumferential wheel speed, m/s;
n - impeller rotation frequency, rpm.

 

Aerodynamic characteristics for fans
with reduced impeller diameter: D = 0,9 Dn and D = 0,95 Dn,

Fan aerodynamic characteristics Aerodynamic characteristics of fans with reduced impeller diameter

 

 

Aerodynamic characteristics for fans
with increased impeller diameter: D = 1,05 Dn and D = 1,1 Dn,

Fan aerodynamic characteristics Aerodynamic characteristics of fans with increased impeller diameter
Reviews

There are no reviews for this product.

There are no reviews for this product, be the first to leave your review.

Answers & questions
Add your question and we will answer as soon as possible.

No questions about this product, be the first and ask your question.