D #10 w/motor AIR 200 L6 30 kW 1000 rpm, execution 3

Exhauster

Brand: КВЗ
0
All about product
Description
Specification
Aerodynamic Characteristics
Dimensions
Reviews 0
Questions0
In Stock
Product Code: ID36082
323 053₴
Found cheaper?

The D #10 w/motor AIR 200 L6 30 kW 1000 rpm industrial smoke exhauster, manufactured according to design scheme No. 3 – drive to the impeller via an intermediate shaft.

Productivity, м³/h:13200
Pressure, Pa:2520
Delivery
Nova Poshta Nova Poshta
Delivery (saving 10% of the delivery cost) Delivery (saving 10% of the delivery cost)
Self-delivery Self-delivery
D #10 w/motor AIR 200 L6 30 kW 1000 rpm, execution 3
323 053₴
Description

The D #10 w/motor AIR 200 L6 30 kW 1000 rpm smoke exhauster is designed to remove gases from small-capacity boiler plants with a capacity of up to 1 ton of steam per hour, operating on gas and fuel oil. The temperature of the transported gases must not exceed 200°C for smoke exhausters with an impeller made of St3 steel and 400°C for an impeller made of heat-resistant steel grade 09G2S. It is also used for sanitary and technical purposes at metallurgical plants, thermal power stations, etc. Ambient temperature: from -40°C to +40°C.

The smoke exhauster D #10 consists of the following components, which can be purchased separately:

  • spiral scroll housing of the fan D #10
  • impeller of the fan D #10
  • base frame of the fan D #10
  • collector of the fan D #10
  • Electric motor AIR 200 L6

The welded spiral housing of the D #10 w/motor AIR 200 L6 30 kW 1000 rpm smoke exhauster is made of carbon steel; the impeller (overhung arrangement) has forward-curved blades, with base frame, collector, and three-phase Electric motor AIR 200 L6.

The D #10 w/motor AIR 200 L6 30 kW 1000 rpm smoke exhauster with installation scheme #3 has the impeller connected to the drive shaft through a bearing assembly. It is designed for long-term operation; wear resistance is ensured by thickened scroll walls and the application of hard surfacing on the blades. Smooth gas flow is ensured by specially selected inlet and outlet angles of the blades. The smoke exhauster can be made for right- or left-hand rotation; the housing can be rotated from 0 to 270 degrees.

General information about D #10 w/motor AIR 200 L6 30 kW 1000 rpm smoke exhausters:

  • Single-sided suction
  • Spiral scroll housing
  • Forward-curved blades
  • Number of blades: 20
  • Rotation direction: right or left (viewed from the motor side)

Purpose of D #10 w/motor AIR 200 L6 30 kW 1000 rpm smoke exhausters:

The D #10 w/motor AIR 200 L6 30 kW 1000 rpm smoke exhauster is intended for use in power engineering as an exhaust device for equipping steam and hot-water boilers with balanced draft of low and medium capacity (up to 25 t of steam per hour or 20 MW) operating on various types of fuel. The smoke exhauster must be equipped with an effective ash trapping system. Designed for continuous operation both indoors and outdoors in temperate climates. Startup is permitted when the temperature in the housing is not lower than -30°C. The maximum temperature of gases at the smoke exhauster inlet should not exceed +250°C.

Use is permitted with gas and oil-fired boilers with balanced draft, as well as in process installations at enterprises in various industries for sanitary and technical or production purposes (at thermal power plants, metallurgical plants, in chemical industry for gas cleaning and dust collection, etc.).

D #10 w/motor AIR 200 L6 30 kW 1000 rpm smoke exhausters are used in:

  • power engineering
  • gas and oil-fired boiler houses
  • steam and hot-water boilers
  • other sanitary and industrial processes

Operating principle of the D #10 w/motor AIR 200 L6 30 kW 1000 rpm smoke exhauster:

The operating principle of the fan is to move air by transferring the rotational energy of the impeller mounted on the motor shaft. The air mixture entering through the collector passes into the channels between the impeller blades and, under the action of centrifugal force, moves to the periphery of the impeller. The smoke gases with air enter the smoke exhauster by receiving energy from the impeller, are deflected 90 degrees in the radial direction by centrifugal force, and are discharged through the scroll housing to the fan outlet.

Operating conditions of the D #10 w/motor AIR 200 L6 30 kW 1000 rpm smoke exhauster:

  • As the housing is made of carbon steel, the temperature of gases must not exceed +250°C.
  • When starting the smoke exhauster, the air temperature in the flow part must not be lower than -30°C.
  • Ambient temperature range: -40°C to +40°C.
  • In places where the unit is installed, the root mean square value of vibration velocity from external sources must not exceed 2 mm/s.
  • Dust content of exhaust gases: not more than 2 g/m3.

Positions of the housing for right-hand (RH) and left-hand (LH) rotation, as viewed from the inlet:

Scroll Position Right-Hand (R) D #10 w/motor AIR 200 L6 30 kW 1000 rpm:
Scroll Position D #10 w/motor AIR 200 L6 30 kW 1000 rpm Left-Hand (L)
Specifications
Common
Model
D #10
Motor type
AIR, A
Productivity, м³/h
13200
Pressure, Pa
2520
Max. transported air temperature, °C
250
Pollution limits, mg/m3
200
Weight, kg
1285
Electric motor AIR 200 L6
Common
Model
AIR 200 L6
Motor type
asynchronous
Kind
general purpose industrial motor
Motor series
AIR
Shaft diameter, mm
60
Voltage, V
220/380
Frequency of the current, Hz
50
Power kW
30.0
Vol./Min
1000
n, vol./Min
975
Climatic performance
UZ
Class of protection, IP
54
Efficiency, %
89,8
Power factor, cosφ
0,84
Weight, kg
250
Consumed nominal current, In (A)
62
Dimension (height of rotation axis), mm
200
Phase
3-phase
The ratio of max. torque to rated power, Mmax/Mn
2,2
The ratio of starting current to the nominal, Istart/In
6,5
The ratio of starting torque to rated power, Mstart/Mn
2,1

Aerodynamic characteristics of D #10 w/motor AIR 200 L6 30 kW 1000 rpm

Aerodynamic characteristics of D #10 w/motor AIR 200 L6 30 kW 1000 rpm

Reviews

There are no reviews for this product.

There are no reviews for this product, be the first to leave your review.

Answers & questions
Add your question and we will answer as soon as possible.

No questions about this product, be the first and ask your question.